Transfix Transformers SA
Pole mounted distribution transformers on an overhead reticulation line at dusk
Transfix Transformers SA

Built and tested under one roof

Pole mounted and ground mounted distribution transformers, and mini substations, manufactured in South Africa since 2011.

Range
16 to 500 kVA
Voltage
11 kV  ·  22 kV
Quality
SABS ISO 9001
B-BBEE
Level 1  ·  100% black owned
What we build01 / 04

Two products, one factory

Everything Transfix ships is wound, assembled, filled, tested and finished at Botshabelo, 48km east of Bloemfontein. Nothing is badge engineered and nothing is drop shipped.

A three phase pole mounted distribution transformer, radiator fins and bushings visible

Distribution transformers

Oil immersed, three phase, medium voltage to low voltage. Pole mounted and ground mounted, at 11 kV and 22 kV, in inland or coastal specification.

16 / 25 / 50 / 100 / 200 / 315 / 500 kVA

View the range
A Transfix mini substation, three quarter view with the doors closed

Mini substations

Safe, reliable distribution in a single enclosure, for industrial, commercial and utility applications. Inland or coastal.

315 & 500 kVA · 11 / 22 kV · 420 V

View the range
Why it matters02 / 04

Manufactured here, not imported

Transfix is one of a small number of plants in South Africa manufacturing medium and low voltage distribution transformers.

The factory was built to European standards under Groupe Cahors and has been in South African hands since 2017. The technology, the tooling and the intellectual property stayed in the building, and so did the people who knew how to use it.

Read our story
Finished Transfix transformers in the yard at Botshabelo, ready for dispatch
Local content
Proudly South African
Transformation
Level 1  ·  135% recognition
Supplier status
Approved Eskom vendor
Workforce
Just under 40, Botshabelo
Testing03 / 04

No transformer leaves Botshabelo untested

Routine production tests are carried out on every unit before dispatch, from winding resistance through to rating plate verification. Type tests verify the design itself. Diagnostic tests are run where your specification or our own quality process calls for them.

See the full test schedule
  • Winding resistanceJoints, connections
  • Insulation resistanceMoisture, contamination
  • Turns ratioTap connections
  • Polarity, vector groupDyn11
  • Applied voltage withstandMain insulation
  • Oil dielectric, moistureOil condition
  • Rating plate verificationPlate against build
Specification04 / 04

Built for where it stands

Coastal air is corrosive, and a transformer built for the Highveld will not last on the coast. Every unit in the range is available in a coastal build.

Where a requirement falls outside the standard range, we design to it. Tell us where it is going and we will build it for there.

Phases
3
Cooling
ONAN
Specification
Inland or coastal
Close detail of bushings and terminals on a Transfix transformer tank
Botshabelo, Free State

Let us quote your next project

Send us the specification, the quantity and where it is going. We will come back to you with a price and a lead time.

Request a quote